Skip to content
2000
Volume 19, Issue 9
  • ISSN: 1573-4056
  • E-ISSN: 1875-6603

Abstract

Background: Cone Beam Computed Tomography (CBCT) represents the optimal imaging solution for the evaluation of the maxillofacial and dental area when quantitative geometric and volumetric accuracy is necessary (e.g., in implantology and orthodontics). Moreover, in recent years, this technique has given excellent results for the imaging of lower and upper extremities. Therefore, significant interest has been increased in using CBCT to investigate larger and non-traditional anatomical districts. Objective: The purpose of this work is to review the scientific literature in Pubmed and Scopus on CBCT application beyond head districts by paying attention to image quality and radiological doses. Methods: The search for keywords was conducted in Pubmed and Scopus databases with no back-date restriction. Papers on applications of CBCT to head were excluded from the present work. From each considered paper, parameters related to image quality and radiological dose were extracted. An overall qualitative evaluation of the results extracted from each issue was done by comparing the conclusive remarks of each author regarding doses and image quality. PRISMA statements were followed during this process. Results: The review retrieved 97 issues from 83 extracted papers; 46 issues presented a comparison between CBCT and Multi-Detector Computed Tomography (MDCT), and 51 reviewed only CBCT. The radiological doses given to the patient with CBCT were considered acceptable in 91% of cases, and the final image quality was found in 99%. Conclusion: CBCT represents a promising technology not only for imaging of the head and upper and lower extremities but for all the orthopedic districts. Moreover, the application of CBCT derived from C-arms (without the possibility of a 360 ° rotation range) during invasive investigations demonstrates the feasibility of this technique for non-standard anatomical areas, from soft tissues to vascular beds, despite the limits due to the incomplete rotation of the tube.

Loading

Article metrics loading...

/content/journals/cmir/10.2174/1573405619666230202122947
2023-08-01
2025-07-08
Loading full text...

Full text loading...

/content/journals/cmir/10.2174/1573405619666230202122947
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test