Skip to content
2000
Volume 18, Issue 2
  • ISSN: 1573-4110
  • E-ISSN: 1875-6727

Abstract

Background: The traditional methods for the detection and quantification of Cu2+ and Fe3+ heavy metal ions are usually troublesome in terms of high-cost, non-portable, time-consuming, specialized personnel and complicated tools, so their applications in practical analyses is limited. Therefore, the development of cheap, fast and simple-use techniques/instruments with high sensitivity/selectivity for the detection of heavy metal ions is highly demanded and studied. Methods: In this study, a fluorene-based fluorescent ''turn-off'' sensor, methyl 2-(2-((((9H-fluoren-9- yl)methoxy)carbonyl)amino)-3- phenylpropanamido) acetate (probe FLPG) was synthesized via onepot reaction and characterized by 1H-NMR, 13C-APT-NMR, HETCOR, ATR-FTIR and elemental analysis in detailed. All emission spectral studies of the probe FLPG have been performed in CHCN/HEPES (9/1, v/v, pH=7.4) media at rt. The quantum (φ) yield of probe FLPG decreased considerably in the presence of Cu2+ and Fe3+. The theoretical computation of probe FLPG and its complexes were also performed using density functional theory (DFT). Furthermore, bio-imaging experiments of the probe FLPG was successfully carried out for Cu2+ and Fe3+ monitoring in living-cells. Results: The probe FLPG could sense Cu2+ and Fe3+ with high selectivity and sensitivity, and quantitative correlations (R2>0.9000) between the Cu2+/Fe3+ concentrations (0.0−10.0 equiv). The limits of detection for Cu2+ and Fe3+ were found as 25.07 nM and 37.80 nM, respectively. The fluorescence quenching in the sensor is managed by ligand-to-metal charge transfer (LMCT) mechanism. Job’s plot was used to determine the binding stoichiometry (1:2) of the probe FLPG towards Cu2+ and Fe3+. The binding constants with strongly interacting Cu2+ and Fe3+ were determined as 4.56×108 M-2 and 2.02×103+ M-2, respectively, the fluorescence titration experiments. The outcomes of the computational study supported the fluorescence data. Moreover, the practical application of the probe FLPG was successfully performed for living cells. Conclusion: This simple chemosensor system offers a highly selective and sensitive sensing platform for the routine detection of Cu2+ and Fe3+, and it keeps away from the usage of costly and sophisticated analysis systems.

Loading

Article metrics loading...

/content/journals/cac/10.2174/1871520621666210322112005
2022-02-01
2024-11-02
Loading full text...

Full text loading...

/content/journals/cac/10.2174/1871520621666210322112005
Loading
  • Article Type: Research Article
Keyword(s): bio-imaging; copper; DFT; fluorene; Fluorescence sensor; iron
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test