OBJECTIVE: The aim of the investigation was to develop and evaluate matrix type transdermal drug delivery systems (TDDS) of nitrendipine (NTDP). EXPERIMENTAL: The matrix type TDDS of NTDP were prepared by solvent evaporation technique. Ten formulations (composed of Eudragit RL 100 and Hydroxypropyl methyl cellulose in the ratios of 5:0, 4:1, 3:2, 2:3, 1:4 in formulations A1, A2, A3, A4, A5 and Eudragit RS 100 and Hydroxypropyl methyl cellulose in the same ratios in formulation B1, B2, B3, B4, B5 respectively) were prepared. All formulations carried 6 % v/w of carvone as penetration enhancer and 15% v/w of propylene glycol as plasticizer in dichloromethane and methanol as solvent system. The prepared TDDS were evaluated for in vitro release, ex vivo permeation, moisture absorption, moisture content and mechanical properties. The physicochemical interactions between nitrendipine and polymers were investigated by Fourier Transform Infrared (FTIR) Spectroscopy. RESULTS: The maximum drug release in 24 hrs for A series formulations was 89.29% (A4) and 86.17% for B series (B5), which are significantly (p < 0.01) different to the lowest values (57.58 for A1 and 50.64 for B1). Again formulations A4 (flux 23.51 μg/hr/cm2) and B5 (flux 22.98 μg/hr/cm2) showed maximum skin permeation in the respective series. The flux obtained with formulation A4 and B5 meets the required flux (19.10 μg/hr/cm2). The mechanical properties, tensile strength, elastic modulus (3.42 kg/mm2 for A4 and 4.25 kg/mm2 for B5) reveal that the formulations were found to be strong but not brittle. FTIR studies did not show any evidence of interaction between the drug and the polymers. RESULTS: The maximum drug release in 24 hrs for A series formulations was 89.29% (A4) and 86.17% for B series (B5), which are significantly (p < 0.01) different to the lowest values (57.58 for A1 and 50.64 for B1). Again formulations A4 (flux 23.51 μg/hr/cm2) and B5 (flux 22.98 μg/hr/cm2) showed maximum skin permeation in the respective series. The flux obtained with formulation A4 and B5 meets the required flux (19.10 μg/hr/cm2). The mechanical properties, tensile strength, elastic modulus (3.42 kg/mm2 for A4 and 4.25 kg/mm2 for B5) reveal that the formulations were found to be strong but not brittle. FTIR studies did not show any evidence of interaction between the drug and the polymers.

Loading

Article metrics loading...

/content/journals/cdd/10.2174/156720107779314767
2007-01-01
2025-05-02
Loading full text...

Full text loading...

/content/journals/cdd/10.2174/156720107779314767
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error
Please enter a valid_number test